<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<Spase xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.spase-group.org/data/schema" xsi:schemaLocation="http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2_2_2.xsd">
   <Version>2.2.2</Version>
   <NumericalData>
      <ResourceID>spase://VMO/NumericalData/GOES/13/EPS/hepad_s15_PT4S</ResourceID>
      <ResourceHeader>
         <ResourceName>GOES 13 High Energy Proton and Alpha Detector (HEPAD) data at 4 s Resolution in Spacecraft Coordinates</ResourceName>
         <AlternateName>GOES 13 HEPAD S15 data</AlternateName>
         <ReleaseDate>2013-03-31T00:00:00.000</ReleaseDate>
         <Description>The GOES 13 High Energy Proton and Alpha Detector (HEPAD) provides flux measurements of high energy proton and alpha particles.  For more information, please see T. G. Onsager et al. (1996), Operational uses of the GOES energetic particle detectors, in GOES-8 and Beyond, Proc. SPIE, Vol. 2812, edited by E. R. Washwell, pp. 281-290, Bellingham, WA.  These data files contain mainly information on the alpha and proton particle counts and count rates for the HEPAD sensor. Data files contain long descriptive header.</Description>
         <Acknowledgement>NASA-Office of Space Science Applications (United States); NOAA National Environmental Satellite Service (United States); Dr. Terry G. Onsager</Acknowledgement>
         <Contact>
            <PersonID>spase://SMWG/Person/Terry.Onsager</PersonID>
            <Role>PrincipalInvestigator</Role>
         </Contact>
         <Contact>
            <PersonID>spase://SMWG/Person/James.M.Weygand</PersonID>
            <Role>MetadataContact</Role>
         </Contact>
         <InformationURL>
            <Name>GOES N, O, and P Brochure</Name>
            <URL>http://goes.gsfc.nasa.gov/text/brochure/GOES_NOP_print.pdf</URL>
            <Description>Information about the magnetometers onboard GOES 13.</Description>
            <Language>en</Language>
         </InformationURL>
      </ResourceHeader>
      <AccessInformation>
         <RepositoryID>spase://SMWG/Repository/NOAA/SEC</RepositoryID>
         <Availability>Online</Availability>
         <AccessRights>Open</AccessRights>
         <AccessURL>
            <Name>Direct access to the GOES 13 High Energy Proton and Alpha Detector data</Name>
            <URL>http://satdat.ngdc.noaa.gov/sem/goes/data/new_full/</URL>
            <Description>Direct link to the GOES 13 High Energy Proton and Alpha Detector (HEPAD) data in CSV format as well as the energetic particle data from other GOES spacecraft. The data are sorted by year, month, spacecraft, and file type. The file names indicates the data type, spacecraft number, year, month, and resolution. For example, g13_hepad_ap_32s_20100531_20100531.csv, indicates goes 13 magnetometer data at 32 s resolution from start of May 31, 2010 to the end of May 31, 2010.</Description>
         </AccessURL>
         <Format>Text.ASCII</Format>
         <Encoding>None</Encoding>
         <Acknowledgement>NASA; NOAA; Dr. Terry G. Onsager</Acknowledgement>
      </AccessInformation>
      <ProcessingLevel>Calibrated</ProcessingLevel>
      <ProviderResourceName>NOAA GOES 13 HEPAD</ProviderResourceName>
      <ProviderProcessingLevel>Level-2</ProviderProcessingLevel>
      <InstrumentID>spase://SMWG/Instrument/GOES/13/EPS</InstrumentID>
      <MeasurementType>EnergeticParticles</MeasurementType>
      <TemporalDescription>
         <TimeSpan>
            <StartDate>2010-05-04T00:00:00</StartDate>
            <StopDate>2013-05-22T23:59:00</StopDate>
            <Note>Data file may fill out the first month and last month with flags. Time format in data files is year-month-day hour:minute:seconds.</Note>
         </TimeSpan>
         <Cadence>PT32S</Cadence>
      </TemporalDescription>
      <Caveats>Flags=-99999.0</Caveats>
      <Keyword>4 s</Keyword>
      <Keyword>geosynchronous</Keyword>
      <Keyword>GOES</Keyword>
      <Keyword>High Energy Proton and Alpha Detector</Keyword>
      <Parameter>
         <Name>Seconds of the Month</Name>
         <ParameterKey>Time</ParameterKey>
         <Description>Time format in data files is year-month-day hour:minute:seconds.</Description>
         <Support>
            <SupportQuantity>Temporal</SupportQuantity>
         </Support>
      </Parameter>                    
      <Parameter>
      		<Name>Quality flag for all particles that deposit energy the D1 silicon slab.</Name>
      		<ParameterKey>S1_QUAL_FLAG</ParameterKey>
      		<Description>Quality flag non-zero value indicates data quality issue.</Description>
      		<Units>qf</Units>
      		<ValidMin>0</ValidMin>
      		<ValidMax>4294967295</ValidMax>
      		<FillValue>99999</FillValue>
      		<Support>
        		<SupportQuantity>Other</SupportQuantity>
      		</Support>
      </Parameter>        
      <Parameter>
      		<Name>Count of all particles that deposit energy in the D1 silicon slab.</Name>
      		<ParameterKey>S1_COUNT</ParameterKey>
      		<Description>Total counts from all particles that deposit >110 keV in the D1 silicon slab.</Description>
      		<Units>counts</Units>
      		<ValidMin>0.0</ValidMin>
      		<ValidMax>1.0000E+06</ValidMax>
      		<FillValue>-99999</FillValue>
      		<Particle>
      			<ParticleType>Ion</ParticleType>
      			<ParticleQuantity>Counts</ParticleQuantity>
      		</Particle>
      </Parameter> 
      <Parameter>
      		<Name>Count rate of all particles that deposit energy in the D1 silicon slab.</Name>
      		<ParameterKey>S1_COUNT_RATE</ParameterKey>
      		<Description>Counts per second from all particles that deposit >110 keV in the D1 silicon slab.</Description>
      		<Units>counts/s</Units>
      		<ValidMin>1.0000E-01</ValidMin>
      		<ValidMax>1.0000E+04</ValidMax>
      		<FillValue>-99999</FillValue>
      		<Particle>
      			<ParticleType>Ion</ParticleType>
      			<ParticleQuantity>CountRate</ParticleQuantity>
      		</Particle>
      </Parameter> 
      <Parameter>
      		<Name>Quality flag for all particles that deposit energy in the D2 silicon slab.</Name>
      		<ParameterKey>S2_QUAL_FLAG</ParameterKey>
      		<Description>Quality flag non-zero value indicates data quality issue.</Description>
      		<Units>qf</Units>
      		<ValidMin>0</ValidMin>
      		<ValidMax>4294967295</ValidMax>
      		<FillValue>99999</FillValue>
      		<Support>
        		<SupportQuantity>Other</SupportQuantity>
      		</Support>
      </Parameter>        
      <Parameter>
      		<Name>Count of all particles that deposit energy in the D2 silicon slab.</Name>
      		<ParameterKey>S2_COUNT</ParameterKey>
      		<Description>Total counts from all particles that deposit >110 keV in the D2 silicon slab.</Description>
      		<Units>counts</Units>
      		<ValidMin>0.0</ValidMin>
      		<ValidMax>1.0000E+06</ValidMax>
      		<FillValue>-99999</FillValue>
      		<Particle>
      			<ParticleType>Ion</ParticleType>
      			<ParticleQuantity>Counts</ParticleQuantity>
      		</Particle>
      </Parameter> 
      <Parameter>
      		<Name>Count rate of all particles that deposit energy in the D2 silicon slab.</Name>
      		<ParameterKey>S2_COUNT_RATE</ParameterKey>
      		<Description>Counts per second from all particles that deposit >110 keV in the D2 silicon slab.</Description>
      		<Units>counts/s</Units>
      		<ValidMin>1.0000E-01</ValidMin>
      		<ValidMax>1.0000E+04</ValidMax>
      		<FillValue>-99999</FillValue>
      		<Particle>
      			<ParticleType>Ion</ParticleType>
      			<ParticleQuantity>CountRate</ParticleQuantity>
      		</Particle>
      </Parameter>
      <Parameter>
      		<Name>Quality flag for all particles that deposit energy in the photomultiplier tube.</Name>
      		<ParameterKey>S3_QUAL_FLAG</ParameterKey>
      		<Description>Quality flag non-zero value indicates data quality issue.</Description>
      		<Units>qf</Units>
      		<ValidMin>0</ValidMin>
      		<ValidMax>4294967295</ValidMax>
      		<FillValue>99999</FillValue>
      		<Support>
        		<SupportQuantity>Other</SupportQuantity>
      		</Support>
      </Parameter>   
       <Parameter>
      		<Name>Count of all particles that deposit energy in the photomultiplier tube.</Name>
      		<ParameterKey>S3_COUNT</ParameterKey>
      		<Description>Total counts from all particles that create >13.5 keV photoelectrons in the photomultiplier tube.</Description>
      		<Units>counts</Units>
      		<ValidMin>0.0</ValidMin>
      		<ValidMax>1.0000E+06</ValidMax>
      		<FillValue>-99999</FillValue>
      		<Particle>
      			<ParticleType>Ion</ParticleType>
      			<ParticleQuantity>Counts</ParticleQuantity>
      		</Particle>
      </Parameter>
      <Parameter>
      		<Name>Count rate of all particles that deposit energy in the photomultiplier tube.</Name>
      		<ParameterKey>S3_COUNT_RATE</ParameterKey>
      		<Description>Counts per second from all particles that create >13.5 keV photoelectrons in the photomultiplier tube.</Description>
      		<Units>counts/s</Units>
      		<ValidMin>1.0000E-01</ValidMin>
      		<ValidMax>1.0000E+04</ValidMax>
      		<FillValue>-99999</FillValue>
      		<Particle>
      			<ParticleType>Ion</ParticleType>
      			<ParticleQuantity>CountRate</ParticleQuantity>
      		</Particle>
      </Parameter> 
      <Parameter>
      		<Name>Quality flag for all particles that deposit energy in the photomultiplier tube.</Name>
      		<ParameterKey>S4_QUAL_FLAG</ParameterKey>
      		<Description>Quality flag non-zero value indicates data quality issue.</Description>
      		<Units>qf</Units>
      		<ValidMin>0</ValidMin>
      		<ValidMax>4294967295</ValidMax>
      		<FillValue>99999</FillValue>
      		<Support>
        		<SupportQuantity>Other</SupportQuantity>
      		</Support>
      </Parameter>   
       <Parameter>
      		<Name>Count of all particles that deposit energy in the photomultiplier tube.</Name>
      		<ParameterKey>S4_COUNT</ParameterKey>
      		<Description>Total counts from all particles that create >69 keV photoelectrons in the photomultiplier tube.</Description>
      		<Units>counts</Units>
      		<ValidMin>0.0</ValidMin>
      		<ValidMax>1.0000E+06</ValidMax>
      		<FillValue>-99999</FillValue>
      		<Particle>
      			<ParticleType>Ion</ParticleType>
      			<ParticleQuantity>Counts</ParticleQuantity>
      		</Particle>
      </Parameter>
      <Parameter>
      		<Name>Count rate of all particles that deposit energy in the photomultiplier tube.</Name>
      		<ParameterKey>S4_COUNT_RATE</ParameterKey>
      		<Description>Counts per second from all particles that create >69 keV photoelectrons in the photomultiplier tube.</Description>
      		<Units>counts/s</Units>
      		<ValidMin>1.0000E-01</ValidMin>
      		<ValidMax>1.0000E+04</ValidMax>
      		<FillValue>-99999</FillValue>
      		<Particle>
      			<ParticleType>Ion</ParticleType>
      			<ParticleQuantity>CountRate</ParticleQuantity>
      		</Particle>
      </Parameter>
      <Parameter>
      		<Name>Quality flag for all particles that deposit energy in both the D1 and D2 silicon slabs.</Name>
      		<ParameterKey>S5_QUAL_FLAG</ParameterKey>
      		<Description>Quality flag non-zero value indicates data quality issue.</Description>
      		<Units>qf</Units>
      		<ValidMin>0</ValidMin>
      		<ValidMax>4294967295</ValidMax>
      		<FillValue>99999</FillValue>
      		<Support>
        		<SupportQuantity>Other</SupportQuantity>
      		</Support>
      </Parameter>        
      <Parameter>
      		<Name>Count of all particles that deposit energy in both the D1 and D2 silicon slabs.</Name>
      		<ParameterKey>S5_COUNT</ParameterKey>
      		<Description>Total counts from all particles that deposit >110 keV in both the D1 and D2 silicon slabs.</Description>
      		<Units>counts</Units>
      		<ValidMin>0.0</ValidMin>
      		<ValidMax>1.0000E+06</ValidMax>
      		<FillValue>-99999</FillValue>
      		<Particle>
      			<ParticleType>Ion</ParticleType>
      			<ParticleQuantity>Counts</ParticleQuantity>
      		</Particle>
      </Parameter> 
      <Parameter>
      		<Name>Count rate of all particles that deposit energy in both the D1 and D2 silicon slabs.</Name>
      		<ParameterKey>S5_COUNT_RATE</ParameterKey>
      		<Description>Counts per second from all particles that deposit >110 keV in both the D1 and D2 silicon slabs.</Description>
      		<Units>counts/s</Units>
      		<ValidMin>1.0000E-01</ValidMin>
      		<ValidMax>1.0000E+04</ValidMax>
      		<FillValue>-99999</FillValue>
      		<Particle>
      			<ParticleType>Ion</ParticleType>
      			<ParticleQuantity>CountRate</ParticleQuantity>
      		</Particle>
      </Parameter>       
   </NumericalData>
</Spase>
